CARBON CARTRIDGE for AP50/80 |
|
|
|
SEDIMENT CARTRIDGE for AP50/80
|
|
|
|
10" BLOCK CARBON CARTRIDGE for AP50S/80S/100S and AP80/100 SHOP |
|
|
|
10"SEDIMENT CARTRIDGE for AP50S/80S/100S and AP80/100 SHOP |
|
|
|
10" FILTER HOUSINGS for AP50S/80S/100S and AP80/100 SHOP |
|
|
|
BOOSTER PUMP RW |
Operation Diagram |
|
|
AQUAPRO MEMBRANES |
|
|
|
SOLENOID VALVE 12 - 220 volt |
|
|
|
FLOATING SWITCH |
|
|
|
RWRO/DI – Ultra-pure Water Post-filter for RO units |
|
RWRO/DI/CRT has been realized to get an ultra-pure water from any RO unit.
The cartridge RWRO/DI/CRT contains a special mixed-bed resin which can remove 85-95%
of the residual pollutants coming from a RO unit, mostly Nitrates and Silicates.
RWRO/DI/CRT must be placed at the outlet of the RO water (or after the carbon post-filter, in case the RO unit is provided with such filter).
An ultra-pure water is recommended for mixing with salts to prepare high quality artificial salt water. It is also very useful to avoid a proliferation of Calcareous algae (Diatoms).
The lifetime of RWRO/DI/CRT cartridge much depends on residual pollutants concentration of RO water.
Regular controls with a Nitrate test (usually after a production of 2000-2500 liters of RO water) will show when the cartridge is exhausted.
The filter is provided with quick fit-in connectors for RO tubing
Dimension of the Post-Filter RWRO/DI: Ø 12 cm – height 30,5 cm |
Operation Diagram |
|
|
RW RO/DI/CRT -Replacement cartridge for Post-Filter RWRO/DI |
|
|
|
RW07 - RW535 -
Flow meters
Flow meters RW07 and RW535 are absolutely necessary for an accurate measuring of any water flow.
Flow meters RW07 and RW535 are available in 2 models:
- RW07 – Water Flow 0-7 liter/minute – inlet/outlet 3/8” – height 17 cm
- RW535 – Water Flow 5-35 liter/minute – inlet/outlet 1”– height 23,5 cm |
|
|
|
RW/FR - External flow restrictor for RO units
All AQUAPRO RO units, besides Aquapro 50 and Aquapro 80, are provided with an external flow restrictor.
Unlike internal flow restrictors, the external ones assure a more accurate pressure inside the unit and make much easier the regular flushing of the membrane.
RW/FR external flow restrictors must be placed at the outlet of waste water.
RW/FR external flow restrictors are available in 3 different models:
- FR-350 for 50GPD membrane
- FR-420 for 75GPD membrane
- FR-1000 for 100GPD membrane
|
Operation Diagram |
|
|
RW/RAL - Chrome Plated Feed Water Connector with handle
This special connector is provided with a male and a female thread and allows to realize a permanent connection for feeding RO units.It is provided with a check valve with safety nut connection for RO tubing.
RW/RAL connector is available in ½" and ¾" sizes. |
|
|
|
RW/RAB - Chrome Plated Feed Water Diverter with handle
This special connector can be assembled directly to the tap and allows to realize a permanent connection for feeding RO units.
Thanks to its additional nipple, it can be used bot for male and female connections.
|
|
|
|
RWMW - Automatic 12V Flushing Kit for RO units
RWRM is a special device for flushing automatically the mambrane in any RO unit provided with an external flow restrictor.
RWRM flushing kit must be placed between the waste water outlet and the flow restrictor and must be connected to a timer, according to the wanted flushing time and/or frequency.
|
Operation Diagram |
|
|
ELECTRONIC DIGITAL FLOW METER DIGIFLOW 8000T
The DigiFlow 8000T incorporates a microprocessor control circuit and a magnetic turbine sensor to calculate the flow rate and flow volume. The DigiFlow 8000T can monitor a single filter by flow rate or flow volume, which can be programmed by the user. The user can program it to either display the real flow rate or volume, or count down from the programmed flow rate or volume and generate a sound alert when it reaches the end.
Features:
- User can program the DigiFlow
- Monitors a single filter
- Power source is two AAA alkaline batteries which last for more than two years
- Status is automatically memorized when power is off
Specifications:
- Capacity counters: 1
- Flow rate reading: Yes
- Capacity setting range: 100- 9900 gallons
- Timing setting range: 30-720 days
- Flow rate range: 0.3-3.5 gpm
- Accuracy: +/-5%
- Connection: 3/8" NPT
- Working temperature: 40- 100°F
- Working pressure: 8-100 psi
- Unit: Gallon
- Power: 3 VDC, 2 x AAA Battery
- End of capacity buzzer alert: Yes
- Dimension: 74 W x 70 H x 52 T
|
|
|
|
In-line Dual Electronic TDS monitor
FEATURES
- Displays TDS levels of the feed water and product water with in & out electrode probes.
- Highly efficient and accurate due to its advanced microprocessor technology.
- Auto-Off function conserves battery power. The unit shuts off automatically after 10 minutes of non-use.
- Dual Range 0-9990 ppm (From 0 - 999 ppm the resolution is 1 ppm. From 1000 to 9990 ppm, the resolution is 10 ppm, indicated by a blinking 'x10' image.)
- Comes equipped with John Guest Quick-Connect T-fittings as shown.
- Installs quickly and easily.
SPECIFICATIONS
- Range: 0-9990 ppm
- Accuracy: ±2%
- Cable Length: 24.5" (including sensor)
- Fittings: 1/4" standard
- Power source: 2 x 1.5V button cell batteries (included)
- Battery life: approx. 1000 hours of continuous use
- Size: 7.6 x 2 x 4.7 cm (3 x .8 x 1.9 in .)
- Weight: 79.4 g ( 2.8 oz .)
|
|
|
|
Anti-Nitrate in-line kit for RO units
The Anti-Nitrate in-line kit has been realized to eliminate residuals of Nitrates from RO water.
It must be placet at the RO water’s outlet and can be used with any kind of RO unit.
The life of the cartridge RW DI/IN/CRT depends from the content of Nitrate of RO water.
It is normally enough to treat 2000-2500 liters of RO water. |
|
|
|
RW DI/IN/CRT replacement cartridge. |
|
|
|
Membrane’s vessel for all AQUAPRO RO units |
|
|
|
Housing wrench for 10” and 20” filters |
|